Viewing Use Vs Weather Charts and Data
To vew the results of the baseline weather analysis for a selected meter, click the Use Vs Weather tab from the Cost Avoidance Manager.

Click the Summer or Winter Display option to view the cooling months or the heating months in the data table and associated Use Vs Weather graph.
NOTE: EnergyCAP uses the building Balance Point Temperature (BPT, as set in the Meter Properties window and the CAP tab), as well as the Min[imum] Degree Day Per Day limit (configured in the Cost Avoidance tab of the Options window) to determine which months have sufficiently severe weather to qualify as heating or cooling months (see Tools > Options – Global > Cost Avoidance tab).
The statistical linear regression chart will show the results of plotting each baseline bill (as listed in the table) on the grid: use/day on the vertical and monthly average degree days on the horizontal.
Since the highest degree day (DD) points are on the right and the highest usage points are at the top, a meter that has a usage vs. weather correlation will have a line that rises from left to right.